According to the "source control and classified management" principle of the Noise Pollution Prevention and Control Law, enterprises bear the primary responsibility for cooling tower noise pollution. GB 12348-2008 (2025 edition) clearly stipulates that the daytime noise level should be 55 dB(A) and the nighttime noise level should be 45 dB(A) in Class 1 areas (residential areas) , and even higher limits should be set for Class 4 areas (major traffic arteries). Exceeding these limits will result in legal penalties. Cooling tower noise control has the dual value of "green production compliance" and "harmonious community co-construction." The following section will systematically analyze the causes of noise pollution and comprehensive control solutions.
Causes of cooling tower noise
Cooling tower noise mainly comes from fan noise , including aerodynamic noise (proportional to the sixth power of the rotational speed) and mechanical vibration noise; secondly, water flow noise , where water droplets hitting the water collection pool generate a high-frequency sound of 70-80 dB(A), the intensity of which is related to the drop height and flow velocity.
Different types of cooling towers have different noise characteristics due to differences in structural design:
Comprehensive governance technical solutions
Adopting a three-tiered governance system of "source-transmission-end":
Source control: Low-noise fan (airfoil blades reduce noise by 5-10dB) + variable frequency speed control (40% speed reduction at night).
Propagation blocking: Impedance composite silencer (noise reduction ≥ 25 dB(A)) + sound barrier
End-of-pipe optimization: honeycomb-shaped buffer pad (15dB noise reduction during water flow) + inclined PVC filler (30% speed reduction)
Regulatory standards and compliance requirements
Noise control of cooling towers must strictly adhere to national and local regulations and standards. At the national standard level, the "Emission Standard for Environmental Noise at the Boundary of Industrial Enterprises" GB 12348-2008 (2025 edition) specifies the noise limits for Class 1-4 acoustic functional zones. Specifically, for Class 1 zones (residential areas), the limit is 55 dB(A) during the day and 45 dB(A) at night , while for Class 4 zones (both sides of main traffic arteries), the limit is 70 dB(A) during the day and 55 dB(A) at night. The nighttime limit is generally 10 dB stricter than the daytime limit.
Under special operating conditions, nighttime frequent noise (≥4 times/hour) must be reduced by 5dB beyond the limit, and sudden noise peaks must not exceed the limit by 15dB. According to the "Noise Pollution Prevention and Control Law," enterprises exceeding noise emission standards will face fines ranging from 200,000 to 2 million yuan. Sensitive areas must also implement special period registration and public disclosure. In Class 1 areas, exceeding the nighttime standard by 5dB triggers rectification, and peak noise exceeding 15dB is directly considered illegal. Enterprises must establish systematic noise control to mitigate risks.
Maintenance and Management Recommendations
Implement full-cycle management and control measures including "quarterly maintenance + water quality management + intelligent regulation":
Quarterly maintenance: Dust removal from fan blades, lubrication of bearings with No. 3 lithium-based grease, and inspection of the water distribution system.
Water quality management: Monthly pH monitoring, semi-annual packing material cleaning
Intelligent adjustment: A 20% speed reduction is triggered by a water temperature threshold adjustment.
The industry needs to continue to take technological innovation as the foundation, management optimization as the key, and policy standards as the guide, so as to ultimately achieve the social responsibility goal of "quiet production and harmonious coexistence".